Code: E511
Description: Color PC Drum Motor's turning at abnormal timing
- The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains
stationary.
- The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains
stationary.
Causes: • Color PC Drum Motor (M2) • Mechanical Control Board (PWB-M)
Remedy: 1 M2 operation check PWB-M CNDM3-5 (REM) PWB-M CNDM3-8 (LOCK) C-23 2 Change PWB-M