Code: E603
Description: Black TCR Sensor adjustment failure
- TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
- TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /K • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean or correct each contact of the Photoconductor Unit if faulty. - - 2 M7 operation check PWB-M CNDM3-10 to 13 C-23 3 Reinstall Photoconductor Unit /K - - 4 Change Photoconductor Unit /K - - 5 Change PWB-M - - 6 Change PWB-P