Code: E621
Description: BLACK PC Drum sensor malfunction
- The output from the Black PC Drive Main and Sub Sensors remains unchanged for a continuous period of 1,000 ms while the Main Motor is turning stably and the Lock signal is active (LOW-0).
- The output from the Black PC Drive Main and Sub Sensors remains unchanged for a continuous period of 1,000 ms while the Main Motor is turning stably and the Lock signal is active (LOW-0).
Causes: • Transport Drive Assy • Mechanical Control Board (PWB-M) • Harness
Remedy: 1 Check if the Detect Light Shield Plate has damages and is properly installed, and correct as necessary. - - 2 Check the Transport Drive Assy connector for proper connection and correct as necessary. - - 3 Check the PWB-M connector for proper connection and correct as necessary. - - 4 Change the cable that connects Transport Drive Assy and PWB-M. - - 5 Change Transport Drive Assy - - 6 Change PWB-M