Code: E630
Description: IDC Sensor (front) failure
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 0.5 V or less, or 4.3 V or more at output checking during IDC Sensor adjustment.
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 1.9 V or less, or 4.4 V or more at density setting during IDC Sensor adjustment.
- The output of Sensor photo-receiver section from the detection point (toner pattern on the Image Transfer Belt) is 1.0 V or less after the adjustment.
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 0.5 V or less, or 4.3 V or more at output checking during IDC Sensor adjustment.
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 1.9 V or less, or 4.4 V or more at density setting during IDC Sensor adjustment.
- The output of Sensor photo-receiver section from the detection point (toner pattern on the Image Transfer Belt) is 1.0 V or less after the adjustment.
Causes: IDC Sensor
Remedy: 1 Check that the IDC Sensor is properly installed and correct as necessary. - - 2 Check if the IDC sensor is dirty and correct as necessary. - - 3 Check the IDC Sensor connector for proper connection and correct as necessary. - - 4 Check the PWB-M connector for proper connection and correct as necessary. - - 5 Change the cable that connects IDC Sensor and PWB-M. - - 6 Change the IDC Sensor.