Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E640 — Epson AcuLaser C9200N

Code: E640

Description: Color Shift Test Pattern failure
- The number of points detected in the main scan direction is more or less than the specified value during main scan direction registration correction.
- The number of points detected in the sub scan direction is more or less than the specified value during sub scan direction registration correction.
Causes: • Transfer Belt Unit • IDC Sensor • Photoconductor Unit • PH Unit
Remedy: 1 Check if Transfer Belt has damages and correct as necessary. - - 2 Check that the IDC Sensor is properly installed and correct as necessary. - - 3 Check if the IDC sensor is dirty and correct as necessary. - - 4 Check the IDC Sensor connector for proper connection and correct as necessary. - - 5 Check the PWB-M connector for proper connection and correct as necessary. - - 6 Change the cable that connects IDC Sensor and PWB-M. 7 Change IDC Sensor. 8 Change Photoconductor Unit. 9 Change PH Unit.