Code: E526
Description: ADC Contamination
- SENSOR ASSY ADC (ADC Sensor) error
- SENSOR ASSY ADC (ADC Sensor) error
Causes: • SENSOR ASSY ADC • HARNESS ASSY ADC • PWBA MCU • LV/HVPS
Remedy: 1 Check of dirt and foreign bodies on surface of SENSOR ASSY ADC Are there any dirt or foreign bodies on the SENSOR ASSY ADC surface? Clean to remove any dirt or foreign bodies, and go to step [2]. Go to Step [2]. 2 Check of SENSOR ASSY ADC attachment Is SENSOR ASSY ADC attached correctly? Go to Step [4]. Re-attach, and go to step [3]. 3 Does the error recur when the power is turned ON? Go to Step [4]. End of procedure 4 5 VDC and 24 VDC power supply check to SENSOR ASSY ADC The voltage of P422-2 . P422-4 on PWBA MCU is 24 VDC? And the voltage of P422-8 . P422-4 is 5 VDC? Go to Step [5]. Go to Step [7]. 5 Continuity check of HARNESS ASSY ADC Disconnect P/J422 from PWBA MCU. Do all of the wiring below have normal continuity? J422-8 . J431-1 J422-4 . J431-5 J422-2 . J431-7 Go to Step [6]. Replace HARNESS ASSY ADC. 6 Check after replacement of SENSOR ASSY ADC Replace SENSOR ASSY ADC. Does the error recur when the power is turned ON? Go to Step [7]. End of procedure 7 Power supply check to PWBA MCU Are each of the power voltages being supplied to the following terminals on PWBA MCU from LV/HVPS? P410-1 . P410-2: 3. 3 VDC P410-3 . P410-4: 5 VDC P410-5/6 . P410-7/8: 24 VDC Replace PWBA MCU. Go to Step [8]. 8 Continuity check of HARNESS ASSY MAIN Disconnect P/J410 from PWBA MCU and P/ J502 from LV/HVPS. Do all of the wiring below have normal continuity? J410-1 . J502-1 J410-2 . J502-2 J410-3 . J502-3 J410-4 . J502-4 J410-5 . J502-5 J410-6 . J502-6 J410-7 . J502-7 J410-8 . J502-8 Replace LV/ HVPS. Repair broken or shorted part.