Mã lỗi E510 — Epson AcuLaser CX11F

Code: E510

Description: ROS Motor Failure
- PWBA MCU could not receive signals output from SOS Sensor in ROS within the specified time.
Causes: • ROS ASSY • HARNESS ASSY MAIN • PWBA MCU • LV/HVPS
Remedy: 1 Check of ROS ASSY attachment Re-attach ROS ASSY. Does the error recur when the power is turned ON? Go to Step [2]. End of procedure 2 Continuity check of HARNESS ASSY MAIN Remove ROS ASSY. Disconnect the P/J407 from PWBA MCU. Is the continuity normal between all terminals of J407 . J601? Go to Step [3]. Repair broken or shorted part. 3 5 VDC power supply check to ROS and PWB SOS The voltage of P407-16 . P407-14 on PWBA MCU is 5 VDC? Go to Step [4]. Go to Step [6]. 4 Check after replacement of PWBA MCU Replace PWBA MCU. Does the error recur when the power is turned ON? Go to Step [5]. End of procedure 5 Check after replacement of ROS ASSY Replace ROS ASSY. Does the error recur when the power is turned ON? Go to FIP-1 81 Electrical noise. End of procedure 6 5 VDC power supply check to PWBA MCU The voltage of P410-3 . P410-4 on PWBA MCU is 5 VDC? Replace PWBA MCU. Go to Step [7]. 7 Continuity check of HARNESS ASSY MAIN Disconnect P/J410 from PWBA MCU and P/ J502 from LV/HVPS. Do all of the wiring below have normal continuity? J410-3 . J502-3 J410-4 . J502-4 Replace LV/ HVPS. Repair broken or shorted part.