Mã lỗi E533 — Epson AcuLaser CX11F

Code: E533

Description: Temp Sensor Error
- SENSOR HUM & TEMP detected a temperature below -7°C or over 55°C.
Causes: • SENSOR HUM & TEMP • HARNESS ASSY MAIN
Remedy: 1 Temperature check of printer installation site Has the ambient temperature where the printer is installed fallen to -7‹C or below or reached or risen to 55‹C or more. Ask the customer to improve the installation environment for the printer. Go to Step [2]. 2 Check of SENSOR HUM & TEMP thermistor resistance value Disconnect P/J413 from PWBA MCU. The resistance value of P104-4 . P104-3 is 10k ƒ¶ } 1k ƒ¶ (approx. 20‹C)? Go to Step [3]. Replace SENSOR HUM & TEMP. 3 Continuity check of HARNESS ASSY MAIN Disconnect the P/J413 from PWBA MCU. Is the continuity normal between all terminals of J413 . J104? Replace PWBA MCU. Repair broken or shorted part.