Mã lỗi E546 — Epson AcuLaser CX11F

Code: E546

Description: Duplex Motor Failure
- The MOTOR ASSY DUP (Lower Roll Motor) or MOTOR ASSY DUP INV (Upper Roll Motor) of Duplex is not rotating at the 57 specified speed.
Causes: • MOTOR ASSY DUP • MOTOR ASSY DUP INV • HARNESS ASSY MAIN • HARNESS-ASSY DUP2 • PWBA MCU • LV/HVPS • HARNESS-ASSY DUP1 • PWBA DUP-L
Remedy: 1 Check of MOTOR ASSY DUP (DUP Lower Motor) and MOTOR ASSY DUP (DUP Upper Motor) attachment Are the Lower and Upper MOTOR ASSY DUP attached correctly? Go to Step [2]. Re-attach, and go to step [2]. 2 Check of load of transmission section of MOTOR driving force Do the Gears that transmit rotation of MOTOR rotate smoothly? Go to Step [3]. Replace parts that hinder rotation. 3 Continuity check of HARNESS ASSY MAIN Disconnect the P/J420 from PWBA MCU. Is the continuity normal between all terminals of J420 . J607 (connector on the printer to connect Duplex)? Go to Step [4]. Repair broken or shorted part. 4 Continuity check of HARNESS-ASSY DUP2 Disconnect P/J443 from PWBA DUP-L. Is the continuity normal between all terminals of J443 . P607 (connector on Duplex to be connected to the printer)? Go to Step [5]. Replace HARNESSASSY DUP2. 5 24 VDC power supply check to MOTOR ASSY DUP (DUP Lower Motor) The voltage of both P442-1 . Frame Chassis and P442-2 . Frame Chassis on PWBA DUP-L are 24 VDC? Go to Step [6]. Go to Step [13]. 6 24 VDC power supply check to MOTOR ASSY DUP INV (DUP Upper Motor) The voltage of both J612-6 . Frame Chassis and P612-5 . Frame Chassis on PWBA DUP-L are 24 VDC? Go to Step [7]. Go to Step [12]. 7 Check after replacement of PWBA DUP-L Replace PWBA DUP-L. Does the error recur when the power is turned ON? Go to Step [8]. End of procedure 8 Check after replacement of MOTOR ASSY DUP (DUP Lower Motor) Replace MOTOR ASSY DUP. Does the error recur when the power is turned ON? Go to Step [9]. End of procedure 9 Check after replacement of MOTOR ASSY DUP INV (DUP Upper Motor) Replace MOTOR ASSY DUP. Does the error recur when the power is turned ON? Go to Step [10]. End of procedure 10 Power supply check to PWBA MCU Is the specified DC voltage being supplied to the following terminals on PWBA MCU? P410-1 . P410-2: 3. 3 VDC P410-3 . P410-4: 5 VDC P410-5/6 . P410-7/8: 24 VDC Replace PWBA MCU. Go to Step [11].

← Xem tất cả mã lỗi Epson AcuLaser CX11F

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie