Code: E516
Description: Communication Error Duplex
- A communication error occurred between PWBA MCU and Duplex.
- A communication error occurred between PWBA MCU and Duplex.
Causes: • HARNESS ASSY MAIN • HARNESS-ASSY DUP2 • PWBA DUP-L • PWBA MCU
Remedy: 1 Check of Duplex attachment on printer Open and re-attach Duplex. Also, re-connect connector to printer. Does the error recur when the power is turned ON? Go to Step [2]. End of procedure 2 Continuity check of HARNESS ASSY MAIN Open Duplex, and disconnect the connector to the printer. Disconnect the P/J420 from PWBA MCU. Is the continuity normal between all terminals of J420 . J607? Go to Step [3]. Repair broken or shorted part. 3 Continuity check of HARNESS-ASSY DUP2 of Duplex Open Duplex, and disconnect the connector to the printer. Disconnect P/J443 from PWBA DUP-L. Is the continuity normal between all terminals of J443 . P607? Go to Step [4]. Replace HARNESSASSY DUP2. 4 Check after replacement of PWBA DUP-L Replace PWBA DUP-L. Does the error recur when the power is turned ON? Go to Step [5]. End of procedure 5 Check after replacement of PWBA MCU Replace PWBA MCU. Does the error recur when the power is turned ON? Go to Step [6]. End of procedure 6 Continuity check of HARNESS ASSY MAIN Disconnect P/J410 from PWBA MCU and P/ J502 from LV/HVPS. Is the continuity normal between all terminals of J410 . J502? Replace LV/ HVPS. Repair broken or shorted part.