Code: E517
Description: Communication Error Feeder
- A communication error occurred between PWBA MCU and Feeder.
- A communication error occurred between PWBA MCU and Feeder.
Causes: • HARNESS ASSY MAIN • HARNESS-ASSY FEED 1 • HARNESS-ASSY FEED 2 • PWBA TRAY 500 • PWBA MCU • LV/HVPS
Remedy: 1 Check of Feeder attachment on printer Remove and re-attach Feeder. Does the error recur when the power is turned ON? Go to Step [2]. End of procedure 2 Continuity check of HARNESS ASSY MAIN Remove Feeder from the printer. Disconnect P/J421 from PWBA MCU. Is the continuity normal between all terminals of J421 . J608 (connector on the printer to connect Feeder)? Go to Step [3]. Repair broken or shorted part. 3 Does the error recur when the power is turned ON? Go to Step [4]. End of procedure 4 Continuity check of HARNESS-ASSY FEED 1 of Feeder Remove Feeder. Disconnect P/J435 from PWBA TRAY 500. Is the continuity normal between all terminals of J435 . P608 (connector on Feeder to be connected to the printer)? Go to Step [5]. Replace HARNESSASSY FEED 1. 5 Check after replacement of PWBA TRAY 500 Replace PWBA TRAY 500. Does the error recur when the power is turned ON? Go to Step [6]. End of procedure 6 Check after replacement of PWBA MCU Replace PWBA MCU. Does the error recur when the power is turned ON? Go to Step [7]. End of procedure 7 Continuity check of HARNESS ASSY MAIN Disconnect P/J410 from PWBA MCU and P/ J502 from LV/HVPS. Is the continuity normal between all terminals of J410 . J502? Replace LV/ HVPS. Repair broken or shorted part.