Code: E521
Description: BTR 2 Error
- The input of 2nd BTR Retract Sensor does not change when 2nd BTR is initialized.
- The input of 2nd BTR Retract Sensor does not change when 2nd BTR is initialized.
Causes: • HARNESS ASSY MAIN • MOT ASSY MICRO • SENSOR 2BTR RETRACT • HARNESS ASSY ADC • PWBA MCU • LV/HVPS
Remedy: 1 Check of 2ND BTR ASSY attachment Is 2ND BTR ASSY attached correctly? Go to Step [2]. Re-attach, and go to step [2]. 2 Does the error recur when restarting the printer? Go to Step [3]. End of procedure 3 Continuity check of HARNESS ASSY MAIN Disconnect the P/J403 from PWBA MCU. Do all of the wiring below have normal continuity? J403-1 . J600-3 J403-2 . J600-2 J403-3 . J600-1 Go to Step [4]. Repair broken or shorted part. 4 24 VDC power supply check to MOT ASSY MICRO (2nd BTR Retract Motor) The voltage of P403-3 . P403-2 on PWBA MCU is 24 VDC? Go to Step [5]. Go to Step [10]. 5 Check after replacement of MOT ASSY MICRO Replace MOT ASSY MICRO. Does the error recur when restarting the printer? Go to Step [6]. End of procedure 6 5 VDC power supply check to SENSOR 2BTR RETRACT. The voltage of P418-4 . P418-5 on PWBA MCU is 5 VDC? Go to Step [7]. Go to Step [10]. 7 Continuity check of HARNESS ASSY ADC Disconnect the P/J418 from PWBA MCU. Do all of the wiring below have normal continuity? J418-4 . J112-3 J418-5 . J112-2 J418-6 . J112-1 Go to Step [8]. Replace HARNESS ASSY ADC. 8 Check after replacement of SENSOR 2BTR RETRACT Replace SENSOR 2BTR RETRACT. Does the error recur when restarting the printer? Go to Step [9]. End of procedure 9 Check after replacement of PWBA MCU Replace PWBA MCU. Does the error recur when restarting the printer? Go to Step [11]. End of procedure 10 Power supply check to PWBA MCU Are each of the power voltages being supplied to the following terminals on PWBA MCU from LV/HVPS? P410-1 . P410-2: 3. 3VDC P410-3 . P410-4: 5VDC P410-5/6 .P410-7/8: 24VDC Replace PWBA MCU. Go to Step [11]. 11 Continuity check of HARNESS ASSY MAIN Are each of the power voltages being supplied to the following terminals on PWBA MCU from LV/HVPS? J410-1 . J502-1 J410-2 . J502-2 J410-3 . J502-3 J410-4 . J502-4 J410-5 . J502-5 J410-6 . J502-6 J410-7 . J502-7 J410-8 . J502-8 Replace LV/ HVPS. Repair broken or shorted part.