Code: 0045
Description: Defogger fan motor malfunction
- The defogger fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
- The fan motor lock signal remains HIGH for a given period of consecutive time while the defogger fan motor is being rotated.
- The defogger fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
- The fan motor lock signal remains HIGH for a given period of consecutive time while the defogger fan motor is being rotated.
Causes: Defogger fan motor (FM5) MFP board/1 (MFPB/1)
Remedy: 1 Check the FM5 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM5 operation check PRCB PJ9-3 (LOCK) C to D-14 4 Change FM5. 5 Change MFPB/1.