Code: A000
Display: Scan Unable Remove the original document. Turn the power off, then on again.
Description: Image processing cannot be completed correctly because the number of pixels required for image processing is insufficient in the scanned data for the second side of the document.
Remedy: 1 Incorrect correction data for second side CIS unit Execute Set CIS scan area (function code: 55). 2 Second side CIS unit failure Replace the second side CIS unit. 3 Main PCB failure Replace the main PCB ASSY.