Code: 00010000
Display: SERVICE CALL 00010000: PF ENCODER CHECK ERROR
Description: PF motor encoder check error The PF motor makes small revolutions clockwise and counter-clockwise. When it turns, the printer checks the rotary encoder (inside the motor) output signals to make sure the motor is turning at the correct speed/distance. If the encoder sends an incorrect signal, an error occurs.
Remedy: Make sure there is nothing blocking the grid rollers. If that does not solve the problem, check the PF motor encoder connection. If there still is a problem, carry out the tension adjustment or phenol-formaldehyde motor exchange of the phenol-formaldehyde timing belt. If there is not a problem, carry out the following items. • Confirming whether the dirt and dust are not adhering to the PF loop scale and PF encoder. • The cable connector joint of the PF encoder and C362DRV board (CN8) are confirmed. • The PF timing belt tension confirmation/adjustment. In the case that there is not abnormality with above checking I gradually exchange the next part. • PF encoder • PF timing belt • PF loop scale • PF encoder extension cable • C362DRV board