Mã lỗi 00010005 — Epson Stylus Pro 10600

Code: 00010005

Display: SERVICE CALL 00010005: CR MOTOR STEP-OUT
Description: The rotational speed of the CR motor abnormal. (it is long/short period at the time of prescription ).
Remedy: It confirms whether there is not abnormal load etc. at the time of carriage migration and be abnormal no and do the checking of the CR encoder, in the case that the error is not canceled. In the case that there is abnormality: • Encoder pulse detection for T fence (scale 180a) of it comes off/whether or not there is not the contact with a CR encoder • Tension adjustment of the confirmation steel belt • Confirmation of the dirt / paper powder / damage of the T fence (scale 180a) the top • CR encoder exchange • CR motor exchange • C362DRV board exchange

← Xem tất cả mã lỗi Epson Stylus Pro 10600