Mã lỗi 00010010 — Epson Stylus Pro 4400

Code: 00010010

Description: PF Motor PWM output faulty
There may be a case where a current exceeding the specified value flows during PF Motor operation. In such a case, this message is displayed and the printer stops operating. This error can be displayed in the following case: an abnormal load which does not reach the level causing an out-of-step phenomenon "00010001" in the paper feed drive system has occurred and the running speed of the motor has been detected to be too low (by the encoder), so that the current is increased to raise the running speed of the motor. Thus, this message appears to prevent the PF Motor from being overheated.
Causes:
Remedy: 1. Check the load on the PF Motor. • Measure the resistance value of the PF Motor. (17.9 ± 15% [Ohm]) If the PF Motor is found in short mode, replace the C593 MAIN Board at the same time. • Running load of PF Motor (check by manual operation) • Rotation load of PF Roller 2. Replace the Motor Assy., PF 3. Replace the C593 MAIN Board