Mã lỗi 00010004 — Epson Stylus Pro 4800

Code: 00010004

Description: CR Motor Encoder check error
During initial operation at power on or during CR Motor operation, there may be a case where the encoder pulse signal is not input at specified intervals. In such a case, this message is displayed and the printer stops operating.
Causes: • Disconnected FFC for the CR Encoder Sensor. • Disconnected connector for the CR Motor. • Broken wire for the CR Motor Encoder Sensor. • Inverted wiring for A and B pulses. • Inverted wiring for the CR Motor. • CR Motor short • Broken power supply fuse for the PF motor driver (on the Main Board )
Remedy: 1. Check to see if the CR Scale for detection of the encoder pulse is removed. 2. Check for dirt, paper dust or damage to the CR Scale. 3. Check if connection of the CR Encoder Sensor connector or Motor Assy., CR connector. 4. Perform the CR Timing Belt Tension Adjustment 5. Replace the CR Encoder Sensor 6. Replace the Motor Assy., CR 7. Replace the C593 MAIN Board