Code: 0001000F
Description: CR Motor PWM output faulty
There may be a case where a current exceeding the specified value flows during CR Motor operation. In such a case, this message is displayed and the printer stops operating. This error can be displayed in the following case: an abnormal load which does not reach the level causing an out-of-step phenomenon "00010005" in the carriage drive system has occurred and the running speed of the motor has been detected to be too low (by the encoder), so that the current is increased to raise the running speed of the motor. Thus, this message appears to prevent the CR Motor from being overheated.
There may be a case where a current exceeding the specified value flows during CR Motor operation. In such a case, this message is displayed and the printer stops operating. This error can be displayed in the following case: an abnormal load which does not reach the level causing an out-of-step phenomenon "00010005" in the carriage drive system has occurred and the running speed of the motor has been detected to be too low (by the encoder), so that the current is increased to raise the running speed of the motor. Thus, this message appears to prevent the CR Motor from being overheated.
Causes:
Remedy: 1. Check the load on the CR Motor. • Running load of CR Motor (check by manual operation) • Measure the resistance value of the CR Motor. (19.3 ± 10% [Ohm]) • Damage to or wear in the CR Driven Pulley • Damaged or worn bearing of the Carriage Unit • Flaws in the CR Rail caused by roller running • Tension of the CR timing belt 2. Replace the Motor Assy., CR If the CR Motor is found in short mode, replace the C593 MAIN Board at the same time. 3. Replace the C593 MAIN Board unnin