Code: 00010023
Description: RTC analyzing error
The printer causes this error and stops operation when it detects that the absolute date and time stored on the NVRAM is incorrect.
The printer causes this error and stops operation when it detects that the absolute date and time stored on the NVRAM is incorrect.
Causes:
Remedy: 1. Start up the printer in the Serviceman mode, and correct the date and time setting using the “RTC & USB ID & IEEE1394 ID” Basic Adjustment menu provided in the Adjustment Program. 2. Remove and reinstall the lithium battery. 3. Replace the lithium battery. Be sure to perform the RTC setting. 4. Replace the BOARD ASSY., MAIN .