Code: 00010000
Description: PF Encoder check error
The printer causes this error and stops operation if it cannot detect the encoder pulse signals at intervals of the specified time during the power-on initialization operation or while the PF Motor is driving.
The printer causes this error and stops operation if it cannot detect the encoder pulse signals at intervals of the specified time during the power-on initialization operation or while the PF Motor is driving.
Causes: • The PF Encoder connector is disconnected. • The PF Motor connector is disconnected. • The Encoder harness on the PF side is broken. • The wiring of the A and B phases are wrong (opposite) • The wiring of the motor is wrong (opposite) • The PF Motor shorted out. • The PF Motor is energized continuously and kept rotating abnormally. • The fuse for the motor driver is blown. (on the Main Board) • The Main Board is damaged. (+42V/+24V remote control is broken) • The Power Supply Board is damaged (42V is OFF).
Remedy: 1. Clean dirt or paper dust on the Loop Scale and check if it is damaged. 2. Reconnect the PF Encoder connector or the PF Motor connector securely. 3. Execute the PF Timing Belt Tension Adjustment . 4. Replace the PF Encoder Sensor . 5. Replace the PF MOTOR ASSY. . 6. Replace the BOARD ASSY., MAIN .