Causes: • Exact detection of printing positions is impossible due to dirt or scratches on the Timing Fence or the CR Encoder. • Malfunction of the program
Remedy: 1. Replace the SCALE, CR . 2. Replace the CR Encoder Sensor . 3. Execute the CR Encoder Sensor Adjustment . 4. Installing Firmware