Code: 00010027
Description: Pressure pump micro air-leak error
The printer causes the error and stops operation if the Pressure Sensor becomes “LOW” state while performing a inspection of the Pressure Motor by “1.4.6.1 Self Testing Menu (SELF TESTING)” . This error occurs only when the printer is in the SELF TESTING mode. If a micro air leak from the Pressure Motor is suspected because the motor works frequently or constantly, the SELF TESTING function allows you to check it for micro air leak before the printer causes a Service Call 00010014 for leakage of air.
The printer causes the error and stops operation if the Pressure Sensor becomes “LOW” state while performing a inspection of the Pressure Motor by “1.4.6.1 Self Testing Menu (SELF TESTING)” . This error occurs only when the printer is in the SELF TESTING mode. If a micro air leak from the Pressure Motor is suspected because the motor works frequently or constantly, the SELF TESTING function allows you to check it for micro air leak before the printer causes a Service Call 00010014 for leakage of air.
Causes: • Micro air leak from the Pressure Motor. • The Pressure Tube is disconnected. • The pressure inside the pressurizing mechanism dropped within 90 seconds after finishing the last pressurizing operation.
Remedy: 1. Connect the Pressure Tube. 2. Replace the PUMP ASSY., SUPPLY .