Code: 59.XY
Display: 59.XY PRINTER ERROR
Description: A printer motor error has occurred.
X Description: 0 motor error 1 motor startup error 2 motor rotation error 3 fuser motor startup error 4 fuser motor rotation error 5 print cartridge motor startup error 6 print cartridge motor rotation error 9 ETB motor startup error A ETB motor rotation error B developing disengaging motor startup error C developing disengaging motor rotation error
Y Description: 0 no color K black C cyan M magenta Y yellow
X Description: 0 motor error 1 motor startup error 2 motor rotation error 3 fuser motor startup error 4 fuser motor rotation error 5 print cartridge motor startup error 6 print cartridge motor rotation error 9 ETB motor startup error A ETB motor rotation error B developing disengaging motor startup error C developing disengaging motor rotation error
Y Description: 0 no color K black C cyan M magenta Y yellow
Remedy: 1 Turn the printer off and then back on. 2 This message might also appear if the transfer unit is missing or incorrectly installed. Ensure that the transfer unit is correctly installed. ETB motor error 1 Clean the ETB unit intermediate connector, J4017. If the connector is damaged, replace it. 2 Reconnect the connetors J4022 for the ETB motor, J4017 between the ETB and the printer, and J4014 on the DC controller PCB. 3 Replace the ETB motor. 4 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. Fuser motor error 1 Reconnect the connectors J4030 for the fuser motor and J1002 on the DC controller PCB. Replace any damaged parts. 2 Replace the fuser drive assembly. 3 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. See “Calibrate Now” on page 294. Print cartridge motor error 1 Reconnect the print cartridge connector on the DC controller PCB (J1013 for cyan, J1031 for magenta, J1032 for yellow, and J1033 for black). 2 Replace the drum drive assembly for the indicated print cartridge. 3 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller. Developing disengaging motor error 1 Reconnect the connectors J4024 and J1019 between the developing disengaging motor and the DC controller PCB. 2 Replace the developing disengaging drive assembly. 3 Replace the DC controller PCB. Calibrate the printer after replacing the DC controller.