Code: 57.3
Display: 57.3 FAN FAILURE
Description: One of the cooling fans failed. 3 = Fan 3 (FM 3)
Remedy: Caution: Turn the printer off and do not operate the printer in this condition or it can be seriously damaged. 1 Turn the printer off and on to reset it. 2 Reconnect connectors J645 and J647 on the main relay PCA, J18 and J74 relay connectors, and connector J227 on the controller board. 3 Reconnect connector J641 on the main relay PCA, and connector J102 on the power supply. 4 Measure the voltage across J645-3 (FAN3ON) and J645-1 (GND) on the main relay PCA after the printer is turned on. If the voltage changes from 0 V to 24 V, replace fan 3. 5 Measure the voltage across connector J641-1 (+24 VB) and J641-4 (GND) on the main relay PCA after the printer is turned on. If the voltage is not 24 V, replace the main relay PCA. 6 Measure the voltage across connector J641-1 (-24 VB) and J641-4 (GND) on the main relay PCA after the printer is turned on. If the voltage is not 24 V, replace the main relay PCA. 7 Check the AC power supply. 8 If the problem is not rectified after the printer is turned off and on again, find the cause of activation of the overcurrent/overvoltage detection circuit in the power supply. Wait more than two minutes before turning the printer back on. 9 Replace the controller board.