Code: 54.XX
Display: 54.XX PRINTER ERROR
Description: The printer 54 errors indicate sensor abnormalities. Sensor abnormalities are caused by failed or blocked sensors, or sensors reporting results outside an expected range. Note Some 54 errors do not stop the printing process, and are only noted in the event log but not on the control panel. XX description 00 = ITB misalignment (check the event log for a 54.27 error and cycle power to recover) 01 = environmental temperature sensor output is abnormal (appears only in the event log) 05 = OHT sensor failure (appears only in the event log) 06 = density sensor failure Note For errors 11 through 14, the density is set to the highest or lowest possible value. This usually occurs because the calibration patches are not on the ITB correctly. These errors appear only in the event log. 11 = yellow density sensor (the engine detects abnormality in the yellow density control and the engine default is used) 12 = magenta density sensor (the engine detects abnormality in the magenta density control and the engine default is used) 13 = cyan density sensor (the engine detects abnormality in the cyan density control and the engine default is used) 14 = black density sensor (the engine detects abnormality in the black density control and the engine default is used) Note Errors 15 through 18 only appear in the event log and printing continues. 15 = yellow CPR sensor (the engine cannot detect the yellow CPR pattern on the ITB) 16 = magenta CPR sensor (the engine cannot detect the magenta CPR pattern on the ITB) 17 = cyan CPR sensor (the engine cannot detect the cyan CPR pattern on the ITB) 18 = black CPR sensor (the engine cannot detect the black CPR pattern on the ITB) 20 = CPR sensor (output is abnormal or the engine cannot detect any of the CPR patterns on the ITB) Note Errors 21 through 24 indicate a toner concentration sensor failure. 21 = yellow image drum t/d ratio sensor 22 = magenta image drum t/d ratio sensor 23 = cyan image drum t/d ratio sensor 24 = black image drum t/d ratio sensor 27 = ITB misalignment sensor Note 27 = ITB misalignment sensor appears in the event log, but it might appear as a 54.00 error on the control panel. 28 = clean density/CPR sensor warning (only appears in the event log) Note For error 28, the CLEAN SENSORS 54.28.01 (density sensor is dirty) or CLEAN SENSORS 54.28.02 (CPR sensor is dirty) appears on the event log. 29 = clean density/CPR sensor failed (only appears in the event log and CLEAN SENSORS appears on the control panel) 30 = halftone calibration error .
Remedy: • 54.01 procedure: 1 Check that all of the environmental requirements are met. 2 Turn the printer off, and then turn the printer on again. 3 Check connector K3013 on the temperature/humidity sensor, intermediate connector J3085, and connector J807 on the T driver PCA. 4 Replace the temperature/humidity sensor. 5 Replace the T driver PCA. 6 Replace the DC controller PCA. • 54.06, 54.11, 54.12, 54.13, 54.14, and 54.30 procedure: 1 Check the cleaning blade and ITB for evidence of a cleaning blade failure (which might cause the density calibration to fail). 2 Check the right door actuated cleaning mechanism for correct functionality. 3 Select CALIBRATE NOW and PRINT STOP TEST on the control panel to check correct formations of the calibration swatches on the ITB. If the swatches are light or missing a color, check the T1 components, image drum, and print cartridge for the missing or light color. Also, check for malformed or too light swatches, stray toner from cleaning failures, and ITB damage. 4 Check connector J3014 at the density sensor, intermediate connector J3072 and J3080, and connector J808 on the T driver PCA. 5 Replace the density/color registration sensor assembly. 6 Replace the T driver PCA. 7 Replace the DC controller PCA. • 54.05 procedure: 1 Clean the OHT sensor. 2 Check the transparency sensor for correct functionality. 3 Check connectors J3032 on the transparency sensor, intermediate connector J3027, and connector J121 on the DC controller PCA. • 54.15, 54.16, 54.17, 54.18, and 54.20 procedure 1 Check the color and the tray 1 dependent items for the specified color. 2 Defeat the right side upper door (ITB access) interlocks and check during a calibration that the density patches are formed correctly on the ITB. 3 Print a laser alignment page to check for adjustable CPR problems. 4 Check the cleaning blade and ITB for evidence of a cleaning blade failure (which might cause the density calibration to fail), and check the ITB for damage. 5 Check the right door actuated cleaning mechanism for correct functionality. 6 Select CALIBRATE NOW and PRINT STOP TEST on the control panel to check correct formations of the calibration swatches on the ITB (set to 7,000 milliseconds for a CPR pattern check). If the swatches are light or missing a color, check the T1 components, image drum, and print cartridge for the missing or light color. Also, check for malformed or too light swatches, stray toner from cleaning failures, and ITB damage. 7 Check the ITB for smooth belt rotation and belt travel. Replace the ITB if movement problems or damage exists. 8 Check connector J3073 and J3074 at the CPR sensors, intermediate connector J3080, and connector J808 on the T driver PCA. 9 Replace the DC controller PCA. 10 Replace the density/color registration sensor assembly. 11 Replace the T driver PCA. • 54.21, 54.22, 54.23, and 54.24 procedure 1 Turn the printer off, and then turn the printer on again to clear the error. 2 Check the indicated image drum for damaged high-voltage contacts, and check the contacts for continuity to the high-voltage power supply. 3 Check the image drum highvoltage pins on the print engine. 4 Check the following connectors: a Yellow: J3040 and J804 on the T driver PCA. b Magenta: J3038 and J804 on the T driver PCA. c Cyan: J3044 and J805 on the T driver PCA. d Black: J3042 and J805 on the T driver PCA. 5 Replace the indicated image drum. (Make sure that the printer is turned off, and then turned on again after the image drum is replaced.). 6 Replace the T driver PCA. 7 Replace the DC controller PCA. • 54.27 and 54.00 procedure 1 Remove the ITB and check the belt for correct alignment and movement. 2 Replace the ITB and seat it correctly. 3 Check connector J3075 and J618 on the P driver PCA. 4 Replace the ITB. 5 Replace the P driver PCA. 6 Replace the DC controller PCA. • 54.28 procedure 1 Make sure that the density/color sensor shutter is in the open position when the front right door is closed. 2 Open and close the front right door to clean the sensor assembly. 3 Adjust or replace the sensor cleaning assembly that is actuated by the front right door. 4 Replace the density/color registration sensor assembly. • 54.29 procedure 1 Check the right door actuated cleaning mechanism for correct functionality. 2 Adjust or replace the sensor cleaning assembly that is actuated by the front right door. 3 Replace the density/color registration sensor assembly.