Code: 55.X
Display: 55.X Error
Description: The product has experienced a communication timeout error.
The value for X indicates the following issues. • X=0: DC controller communication error • X=0601: DC controller NVRAM data error • X=0602: DC controller NVRAM access error • X=1: DC controller memory error
The value for X indicates the following issues. • X=0: DC controller communication error • X=0601: DC controller NVRAM data error • X=0602: DC controller NVRAM access error • X=1: DC controller memory error
Remedy: 1. Turn off the power by using the power switch, and then wait at least 30 seconds. 2. Turn on the power and wait for the product to initialize. If the error persists, verify that the DC controller connectors are firmly connected. If the error persists, upgrade the firmware. If the error persists, replace the DC controller.