Code: 65.12.35
Display: 65.12.35 Output Device Failure
Description: Stapler malfunction. The stapler self-prime sensor PHOl2 did not activate. This signal is generated by sensor PHOl2 (staple-ready sensor). Sensor PHOl2 is located in the stapler assembly and cannot be serviced. When a new staple cartridge is installed, the stapler goes through the stapling motion 11 times in order to advance the first staple to the proper stapling position. If the staples are not advanced after 11 attempts, the control board notifies the formatter that self-priming has failed.
Remedy: 1. Verify that genuine HP staples are being used and that the staples are the correct type for this stapler. NOTE: Staples come preloaded in the staple cartridge and cannot be ordered separately as a refill from HP. 2. Replace the staple cartridge. 3. If none of the above corrects the problem, replace the stapler/stacker unit.