Description: Finisher - Communication Lost with Stitcher Controller PCA Error occurs when communication between the stacker-controller board and the saddlestitcher- controller board has been lost or interrupted.
Remedy: Control-panel diagnostics: none 1. Make sure that the finisher is properly grounded. • Ensure that the finisher is latched and locked to the engine by tightening the thumbscrew inside the front door. • Ensure that the grounding-frame assembly (the bar with the wheel located between the engine and the finisher) is in the down position with the wheel touching the floor and that the grounding plate is not damaged. NOTE: The grounding-frame assembly is in the up position when the finisher is shipped. It must be lowered when the finisher is installed. 2. Verify that connector J730 on the stacker controller PCA and the wiring between connector J22 on the saddlestitcher controller PCA are fully seated and not damaged. 3. Replace the saddle-stitcher controller PCA. 4. Only if the error persists and none of the previous steps correct the problem, replace the stacker controller PCA.