Code: 66.12.52
Display: 66.12.52
Description: Finisher error - front booklet-stapler motor (M7) The booklet-maker stitch staplers do not move to different locations in relation to the paper like the main stapler. The only movement is through the movement of the rotary cam located on the stapler unit itself, during the actual stapling of the booklet. The stitch-home-position switch (SW7) is part of the front-stitch stapler unit and senses the stapler opening and closing during stapling by the motion of the rotary drive cam. Like SW7, the stitch motor (M7) is also part of the overall-stitch stapler unit and replacement requires the replacement of saddle-stapler assembly. Error occurs when the front booklet-maker stapler-stitching home-position sensor (SW7) does not turn ON when the stitch motor (Front)(M7) has been driven forward for 0.5 seconds. Also occurs when the front booklet-maker stapler-stitching home-position sensor (SW7) does not turn off when the stitch motor (front) (M7) has been driven forward for 0.5 seconds.
Remedy: Control-panel diagnostics: none 1. Check the front-stitch stapler for jammed staples, and then perform the following steps: • Clear jammed staples, and then check the staple unit for damage. Retest the stapler. • If the error continues, check the following items: Make sure that HP-approved staples are used. Replace the staple cartridge with one containing HPapproved staples. If the error continues, replace the saddle-stapler assembly. • If the error persists, but no damage is found, proceed to the next step. 2. If the error persists and no jammed staples are found, perform the following steps: • Verify that connector J8 on the saddle-stitcher controller PCA is fully seated and not damaged. Check the wiring at the rearsaddle- stitch stapler and the saddle-stapler assembly for damage and proper seating. Also inspect the connector that the saddle-stitch-stapler assembly engages inside finisher, for damage and foreign material in the connector as well as for proper seating with the saddle-stitchstapler assembly. • Only if the error persists and none of the previous steps correct the problem, replace the saddlestitcher controller PCA.