Description: The low-voltage power-supply cooling fan (FM5) experienced an error.
Remedy: 1. Reconnect the connectors of the lowvoltage power-supply cooling fan (J2), low-voltage power supply (J6), and the DC controller PCA (J102). 2. Measure the voltage between connectors J2-1 and J2-3 on the lowvoltage power-supply cooling fan right after the product is turned on. If the voltage changes from 0V to approximately 24V, replace the lowvoltage power-supply cooling fan.