Code: 50.3
Display: 50.3 Fuser error
Description: Fuser is defective (abnormally low temperature of the thermistor)
Remedy: 1. Reconnect the connectors of the fuser (J802) and DC controller PCA (J104). 2. Measure the resistance between the connector J802-1 and J802-3 on the fuser. If the resistance is not within the range from approximately 220 kO to 660 kO (at ambient temperatures), replace the fuser. 3. Reconnect the connectors of the fuser power supply unit (J201, J202, J203). 4. Measure the resistance between the connector J801-1 and J801-2 on the fuser. If the resistance is not within the range from approximately 21 O to 25 O (at ambient temperatures), replace the fuser. 5. Replace the fuser. 6. Replace the fuser power supply unit.