Code: 50.7
Display: 50.7 FUSER ERROR
Description: Fuser pressure-release mechanism failure
Remedy: 1. Reconnect the fuser-pressure release sensor intermediate connector J60, and connector J128 on the DC controller PCA. 2. Run the sensor test in the sensor monitor mode to verify that the fuser pressure-release sensor is functioning properly. If it is not, replace the fuser pressure-release sensor. 3. Check the fuser pressure-release sensor flag. If it is damaged, replace the fuser. 4. Run the fuser pressure-release drive test in actuator drive mode to verify that the fuser motor is functioning properly. If it is not, replace the fuser motor. 5. If the message persists, replace the fuser.