Code: 59.A0
Display: 59.X Error
Description: ITB motor start error or rotation error.
- ITB motor rotation error
- ITB motor rotation error
Remedy: 1. Reconnect the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA. 2. Run the ITB motor drive test in the actuator drive mode to verify that the ITB motor is functioning correctly. If it is not functioning correctly, replace the ITB motor unit.