Code: 50.7
Display: 50.7 Fuser Error
Description: The fuser is defective (pressure release mechanism abnormality).
Remedy: 1. Reconnect the connector (J181) on the DC controller PCA. 2. Run the sensor test in the sensor monitor mode to verify that the fuser pressure release sensor is functioning correctly. If it is not, replace the fuser pressure release sensor unit. 3. Check the fuser pressure release sensor flag. If it is damaged, replace the fuser. 4. Run the fuser pressure release drive test in the actuator drive mode to verify that the fuser motor is functioning correctly. If it is not, replace the fuser motor. 5. Replace the fuser.