Description: Bad contact detected in ISS slot3 floater.
Remedy: • Remove the Cyan Ink Cartridge and reinstall it in to the Printer. • Replace the Cyan Ink Cartridge. • Check that the ISS to Cartridge cable (Cyan Ink Cartridge) is not damaged and is correctly connected to the Ink Supply Tubes PCA. • Replace the ISS to Cartridge cable (Cyan Ink Cartridge). • Replace the Ink Supply Tubes and Trailing Cable.