Code: 123x
Description: Sub-Tank Sensor Error (Full or Half)
The Full and Half Sensors on the Sub-Tanks are defective. x = 0: Printhead Number 1 (Black). x = 1: Printhead Number 2 (Light Magenta). x = 2: Printhead Number 3 (Light Cyan). x = 3: Printhead Number 4 (Yellow). x = 4: Printhead Number 5 (Magenta). x = 5: Printhead Number 6 (Cyan).
The Full and Half Sensors on the Sub-Tanks are defective. x = 0: Printhead Number 1 (Black). x = 1: Printhead Number 2 (Light Magenta). x = 2: Printhead Number 3 (Light Cyan). x = 3: Printhead Number 4 (Yellow). x = 4: Printhead Number 5 (Magenta). x = 5: Printhead Number 6 (Cyan).
Remedy: • Enter the Sensors Menu (in Maintenance Mode) and select "Sub Tank Sensor". Then execute ALL the "Full x" and "Half x" options, and check if the Sub-Tank Sensors are functioning correctly. Manually move the Sub-Tank Sensor Plate and if the Sensor responds, it means that it is working correctly. • If any of the Sub-Tank Sensors fail to respond, then replace the corresponding Sub-Tank Sensor. • Make sure that the Sub-Tank Sensor Relay Cables (Left/Right) and the Sub- Tank Sensor Cables are connected correctly and are not damaged. • Replace the Main PCA.