Mã lỗi 124x — HP DesignJet 9000s

Code: 124x

Description: Ink Supply Sensor Error
The Ink Supply Sensor does not change even though the specified time has passed after driving the Ink Supply Motor for the Sub-Tank. x = 0: Printhead Number 1 (Black). x = 1: Printhead Number 2 (Light Magenta). x = 2: Printhead Number 3 (Light Cyan). x = 3: Printhead Number 4 (Yellow). x = 4: Printhead Number 5 (Magenta). x = 5: Printhead Number 6 (Cyan).
Remedy: • Enter the Sensors Menu (in Maintenance Mode) and select "Sub Tank Sensor". Then, execute the "XX Ink Pump" option for each color, and check if the Ink Supply Sensor is functioning correctly. Manually move the gear and if the Sensor responds, it means that it is working correctly. • If any of the Ink Supply Sensors fail to respond, then replace the corresponding Ink Supply Station. • Enter the Motors Menu (in Maintenance Mode) and set the "X Pump Motor" option to "Normal" to drive the Ink Supply Motor. When the Sub- Tank is already full, it will not be checked and therefore ink should be discharged. Once the motor drive has been checked, set it "Stop" immediately. Repeat the process with the other colors. • If any Ink Supply Motor fails, then replace the corresponding Ink Supply Station. • Replace the Main PCA.

← Xem tất cả mã lỗi HP DesignJet 9000s