Code: 14.11:00
Description: Open circuit in the Curing Module. Power is applied to the Curing module and then the current is measured, if the flow of current is not as expected, the system error is displayed
Remedy: • Check all the cables are connected in the Curing Module, try disconnecting and reconnecting them. • Check the power connection to the Heaters control assembly PCA (J9). • Check the cable between the PSU and the cable of the Curing Residual Current Circuit Breaker (RCCD) • Check to see if the Residual Current Circuit Breaker (RCCD) has blown, reset it, if it blows again immediately (or often), this would indicate an error with the Curing Assembly or the RCCD. • Check to see if there is a blown fuse in the Heater Control Assembly (F1 and F2). • Replace the Heater Control Assembly . • Faulty resistor in the Curing Module, replace the heaters in the Curing module .