Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 15.03:00 — HP DesignJet L25500

Code: 15.03:00

Description: Drying system temperature too high. Drying System has exceeded the upper temperature level.
Remedy: • The cooling fans intake is blocked, check there are no obstructions on any of the cooling fans: Dryer, Curing, Top Cover Fans, Rear Fans. • Check if the Dryer IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check the power going to the IR sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30C. • Check the position of the IR sensor is correct, if it is pointing to a position other than the substrate this will cause an error. • Perform the IR sensor diagnostic check 8.3 Heating IR Sensor ËPage 169, to check the values being detect by the IR sensor. Replace the Dryer IR sensor if required ËPage 496.

← Xem tất cả mã lỗi HP DesignJet L25500

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie