Mã lỗi 15.04:00 — HP DesignJet L25500

Code: 15.04:00

Description: Drying system temperature too low. Drying System has exceeded the lower temperature level (below 5C)
Remedy: • Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printerLs operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printerLs location. • Check if the Dryer IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check the power going to the IR sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30c. • Check the position of the IR sensor is correct, if it is pointing to a position other than the substrate this will cause an error. • Perform the IR sensor check 1.8.1 Heating and Curing temp ËPage 195, to check the values being detected by the IR sensor. Replace the Dryer IR sensor if required ËPage 496. • Replace the Heaters Control Assembly ËPage 465.

← Xem tất cả mã lỗi HP DesignJet L25500