Description: Drying fans failure. One or more Drying fans have failed. The firmware has detected there is no feedback from the fans.
Remedy: • Perform the service test 2.4 ËPage 129 to confirm that one or more of the fans is not working. • If none of the fans are working, this would indicate a failure with the PrintMech, or the cables from the PrintMech: • Check the cables from the Printmech. • Replace the Printmech PCA ËPage 482. • If at least one of the fans is working, check if the failed fans are connected, they are replace the failed fans ËPage 351.