Code: 16.03:00
Description: Curing system temperature too high. Curing System has exceeded the upper temperature level (150C).
Remedy: • Check there are no obstructions on any of the cooling fans: Curing, Top Cover Fans, Rear Fans. • Check the Curing IR Sensor Fan is turning and is correctly installed with the fan in the correct orientation. • Check the cables are connected and not damaged. • Replace the Curing IR Sensor & Fan ËPage 510. • Replace the Printmech ËPage 482. • The Curing IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check the power going to the Curing IR sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30C. • Check the position of the Curing IR sensor is correct, if it is pointing to a position other than the substrate this will cause an error. • Perform the Curing IR sensor diagnostic check g8.4 Curing IR sensorh ËPage 170, to check the values being detected by the Curing IR sensor. Replace the Curing IR sensor if required ËPage 510. • Ensure there are no other addition external sources of heat, such as strong sunlight, powerful lights or heaters.