Mã lỗi 16.05:00 — HP DesignJet L25500

Code: 16.05:00

Description: Problem with the Curing System Temperature Sensor. Signal error detected with the Curing System Temperature Sensor.
Remedy: • Check the Curing IR Sensor Fan is turning and is correctly installed with the fan in the correct orientation. • Check the cables are connected and not damaged. • Replace the Curing IR Sensor & Fan ËPage 510. • Replace the Printmech ËPage 482. • check if the Curing IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check the power going to the IR sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30c. • Perform the IR sensor diagnostic check g8.4 Curing IR sensorh ËPage 170, to check the values being detected by the IR sensor. Replace the Curing IR sensor if required ËPage 503.