Code: 16.09:00
Description: Curing System fans failure. The array of Curing System fan is not connected or has failed.
Remedy: • Perform the service test 2.4 ËPage 129 to confirm that one or more of the fans is not working. • If none of the fans are working, this would indicate a failure with the PrintMech, or the cables from the PrintMech: • Check the cables from the Printmech. • If all the cables from the Printmech to the fans are connected, replace the Printmech ËPage 482. • If at least one of the fans is working, check if the failed fans are connected, if they are replace the failed fan (Top Cover Fans ËPage 349 or Rear Cover Fans ËPage 351, Curing Fans ËPage 503.