Description: Unable to pressurize the IDS. The IDS must be pressurized but the requested pressure is not achievable in the time given (120 seconds).
Remedy: • Perform the APS service test ËPage 146 • Check the air pumps are correctly connected. • Check the cables from the PrintMech to the Air Pump are connected and not damaged. • Check that the air tubes connected to the air pressure sensor are not pinched and are correctly connected. • Check that the air tubes are connected, as this issue could cause this system error to be displayed • Check the Primer air tubes are connected and not damaged. • Tap on the relief valve with a screw driver several times to release it from a pressure blockage. • Remove ALL the Ink Cartridges and reinstall them one by one in to the Printer. • Replace the APS Assembly . • Replace the ISS PCA