Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 15.05:00 — HP DesignJet L26500

Code: 15.05:00

Description: Problem with the Drying System Temperature Sensor. Signal error detected with the Drying System Temperature Sensor.
Remedy: • Check that none of the air intakes of any of the fans are blocked • Check if the Dryer IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check the power going to the IR sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30c. • Perform the IR sensor diagnostic check 8.3 Heating IR Sensor ËPage 169, to check the values being detected by the IR sensor. Replace the Dryer IR sensor if required ËPage 496.

← Xem tất cả mã lỗi HP DesignJet L26500