Code: 15.06:00
Description: Temperature error detected. There is a mismatch between the temperature detected by the Drying IR Sensor and the amount of electrical power the Drying System is receiving
Remedy: • The ink density is too high, check the UserLs Manual for the recommended ink density levels. • Check if the input voltage is in the range of 198v to 205v, ensure the ambient temperature is higher than 20C for the correct functioning of the printer. • Check if the substrate loaded on the printer is too transparent or reflective for the IR sensor to detect the surface temperature. Check this by loading another type of substrate. • Check that power is going to the IR Sensor, a good indication of this is the blue LED lights if the sensor is pointing to an object warmer than 30c • Check if the Dryer IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check the position of the IR sensor is correct, if it is pointing to a position other than the substrate this will cause an error. • Perform the IR sensor check 1.8.1 Heating and Curing temp ËPage 195, to check the values being detected by the IR sensor. Replace the Dryer IR sensor if required ËPage 496. • Replace the Heaters Control Assembly ËPage 465. • If there is power going to the heater, but the heater does not come on, replace the heater ËPage 498. • Check the voltage supplied to the Printer is inside the Printers functional specifications. • Check the quality of the AC line going into the printer.