Code: 16.01:00
Description: Curing Module warm up time out. Curing System unable to warm up in the pre-defined amount of time: 9 minutes (45C for standby & normally 95C for printing).
Remedy: • Check if the environmental ambient temperature is too low. Check the surrounding temperature is within the printerLs operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printerLs location. • Check if the input voltage is in the range of 198v to 205v, ensure the ambient temperature is higher than 20C for the functioning of the printer. • Check if the substrate loaded on the printer is too transparent or reflective for the Curing IR sensor to detect the surface temperature. Check this by loading another type of substrate. • Check if the Curing IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check for an obstacle blocking the IR sensorfs view. Ensure the IR sensor is correctly installed on the printer, with no interference in the IR path • Check the power going to the Curing IR sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30c. • Check the position of the Curing IR sensor is correct, if it is pointing to a position other than the substrate this will cause an error. • Perform the IR sensor diagnostic check 8.4 Curing IR sensor ËPage 170, to check the values being detected by the IR sensor. Replace the Curing IR sensor if required ËPage 510. • Check if the input voltage is inside the range of specifications for printing, check the installation instructions. • Replace the Heaters Control Assembly . • If the power arrives to the heater, but the heater does not heat up, replace the heaterLs in the Curing AssemblyËPage 498.