Mã lỗi 16.03:00 — HP DesignJet L26500

Code: 16.03:00

Description: Curing system temperature too high. Curing System has exceeded the upper temperature level (150C).
Remedy: • Check there are no obstructions on any of the cooling fans: Curing, Top Cover Fans, Rear Fans. • Check the Curing IR Sensor Fan is turning and is correctly installed with the fan in the correct orientation. • Check the cables are connected and not damaged. • Replace the Curing IR Sensor & Fan ËPage 510. • Replace the Printmech ËPage 482. • The Curing IR sensor is dirty and requires cleaning, use the cleaning procedures described in the Userfs Guide while observing all safety precautions while working in the area of the heaters. • Check the power going to the Curing IR sensor. A good indication is that the blue LED on the sensorfs body will light if the sensor is pointing to an object warmer than 30C. • Check the position of the Curing IR sensor is correct, if it is pointing to a position other than the substrate this will cause an error. • Perform the Curing IR sensor diagnostic check g8.4 Curing IR sensorh ËPage 170, to check the values being detected by the Curing IR sensor. Replace the Curing IR sensor if required ËPage 510. • Ensure there are no other addition external sources of heat, such as strong sunlight, powerful lights or heaters.